Your ultimate defence against corrosion. Follow our expert guidelines to ensure long-lasting protection for every surface.
Ensure surfaces are degreased and free of contamination using Protective Paints A925 – Metal degreaser (follow instructions as per data sheet). Ensure all Corroless data sheet are strictly followed. Ensure surfaces are free from preparation debris and are clean and dry. Apply 1st coat within 4 hours of abrasive blasting. Practical coverage is project dependent.
All data sheets can be found at the back of this manual.
Abrasive Blasting Sa 2½ of AS 1627.4 (Two pack system)
Less Than 10 km from coastal areas of industrial activity
Abrasive Blasting Sa 2½ of AS 1627.4 (Two pack system)
Apply Corroless EPF at 210 µ WFT( 200 µ DFT)
Tank Lining of
Abrasive Blasting Sa 2½ of AS 1627.4 (Two pack system)
Apply Corroless EPF at 210 µ WFT( 200 µ DFT)
Apply Corroless RF 35 at 210 µ WFT ( 200 DFT)