Your ultimate defence against corrosion. Follow our expert guidelines to ensure long-lasting protection for every surface.

Maintenance Repaint

No paint system will give optimum performance over poorly prepared surfaces. Painting over dirt, dust or contaminated surfaces is wasteful in terms of time, materials and labour.
The aim in preparation is to remove contamination, glossiness and defect of the surface in order to provide a physically sound and chemically clean surface. Ensure surfaces are degreased and free of contamination using Protective Paints A925 – Metal degreaser (follow instructions as per data sheet). Ensure surfaces are free from preparation debris and are clean and dry. Apply 1st coat within 4 hours of abrasive blasting. Practical coverage is project dependent.
All data sheets can be found at the back of this manual.

Internal / External Mild Exposure
5 – 10 years to first maintenance to
AS/NZ 2312

Away from coast and industrial activity Power tool clean to rust effected area to AS 1627.2 Class 3 Abrade coating feathering edges removing gloss/chalking
1st Coat

Apply Corroless S1 or S2 at 90 µ WFT (40 µ DFT)

2nd and 3rd coat

Apply Corroless RF 15 at 80 µ WFT (40 µ DFT ) tinted
to miox colours

TDF = 120 microns minimum

Internal / External Wet Exposure
5 – 10 years to first maintenance to
AS/NZ 2312

Preparation: Abrasive Blasting Sa 2½ of AS 1627.4.
Two pack system

1st Coat

Apply Corroless E at 135 µ WFT( 75 µ DFT)

2nd and 3rd coat
Apply Corroless RF 60 at 50 µ WFT ( 30 DFT)

TDF = 135 microns minimum

Specification subject to NZS/AS 1627; Preparation of surfaces NZS/AS 2312 Protection of mild steel; AS 3894 Determination of Dry Film thickness