Ensure surfaces are degreased and free of contamination using Protective Paints A925 – Metal degreaser (follow instructions as per data sheet). Ensure all Corroless data sheet preparation procedures are strictly followed. Ensure surfaces are free from preparation debris and are clean and dry. Apply 1st coat within 4 hours of abrasive blasting. Practical coverage is project dependent. All data sheets can be found at the back of this manual.
Geothermal Hydrothermal steam pipes and bores
Abrasive Blasting Sa 2½ of AS 1627.4 (Two pack system)
Abrasive Blasting Sa 2½ of AS 1627.4 (Two pack system)
Apply Corroless EPF at 210 µ WFT( 200 µ DFT). Spread
100g/m2 of aluminium oxide into wet coating
Abrasive Blasting Sa 2½ of AS 1627.9 (Two pack system)
Apply Corroless EPF at 210 µ WFT( 200 µ DFT)
Apply Corroless EPF at 210 µ WFT( 200 µ DFT)